Customization, Titanium Electrode Set for Bathtub Disinfection

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 24 Month
Manufacturer/Factory, Other, Group Corporation
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
32800000 HKD
Plant Area
>2000 square meters
  • Customization, Titanium Electrode Set for Bathtub Disinfection
  • Customization, Titanium Electrode Set for Bathtub Disinfection
  • Customization, Titanium Electrode Set for Bathtub Disinfection
  • Customization, Titanium Electrode Set for Bathtub Disinfection
  • Customization, Titanium Electrode Set for Bathtub Disinfection
  • Customization, Titanium Electrode Set for Bathtub Disinfection
Find Similar Products
  • Overview
  • Detailed Photos
  • Product Description
  • Product Parameters
  • Installation Instructions
  • Packaging & Shipping
  • Certifications
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
TEBD SERIES
Type
Microfiltration Machine
Method
Chemical Treatment
Usage
Industrial, Home, Agriculture, Hospital, Nuclear Wastewater Treatment
Application
Treatment of Medical Wastewater
Ti Content (%)
99.6%
Grade
Titanium Grade 1
Technique
Sanding Blasting, Acid Washing, Brush Coating
Processing Service
Bending, Welding, Decoiling, Cutting, Punching
Available Anode Type
Mesh, Sheet/Plate,Bar/ Rod/Wire, Pipe/Tube
Available Coating Type
IR02-Ruo2-TiO2-X /Iro2-Tao5/PT/Nb/Ta
Coating Color
Black
Support Design&Customize
Yes
Maximum Order Quantity
1 Set
Lead Time
5-7 Days
Transport Package
Individual Packing + Wooden Box
Specification
MMO Titanium electrode set
Trademark
CHB or customization
Origin
China
Production Capacity
20000PCS

Product Description

Customization, Titanium Electrode Set for Bathtub Disinfection 
Detailed Photos


Customization, Titanium Electrode Set for Bathtub Disinfection



Customization, Titanium Electrode Set for Bathtub Disinfection

Product Description

The Importance of Bathtub Disinfection

1, Health and Safety:

** Bathtubs, being frequently touched items in daily life, can harbor bacteria, viruses, and mold if not disinfected regularly. These microorganisms can lead to skin infections, respiratory illnesses, and other health issues.

** Regular bathtub disinfection reduces the risk of cross-contamination, especially important for households with children, seniors, or individuals with weakened immune systems.

2,  Preserving Bathtub Quality:

**Neglecting to clean and disinfect a bathtub allows dirt and scale buildup, which can corrode and damage the tub material, shortening its lifespan.
**Disinfection removes these contaminants, maintaining the tub's cleanliness and smoothness, thereby extending its useful life.

3,  Enhancing User Experience:
A clean, odor-free bathtub provides a better bathing experience, fostering a sense of cleanliness and relaxation.



Working Principle of Titanium Electrode Disinfection:

1,  Electrolysis Process:

**When an electric current passes through an electrolytic cell containing an electrolyte (such as sodium chloride solution), the titanium electrode serves as the anode, participating in the electrolytic reaction.

**At the anode, oxidation occurs, where chloride ions (Cl-) lose electrons to form chlorine gas (Cl2), which can further react with water to produce hypochlorous acid (HClO) and other strong oxidizing agents.
At the cathode, reduction occurs, generating hydroxide ions (OH-) and hydrogen gas (H2).

2,  Generation of Strong Oxidizing Agents:

The chlorine gas or hypochlorous acid generated during electrolysis possess potent bactericidal properties.
These strong oxidizing agents rapidly disrupt the cell walls and membranes of bacteria, viruses, and other microorganisms, causing their internal contents to leak out, thereby achieving disinfection.

3,  Advantages and Characteristics:

**Environmentally Friendly: Electrolytic disinfection eliminates the need for additional chemical disinfectants, reducing chemical usage and discharge, making it more eco-friendly.
**High Efficiency: The strong oxidizing agents produced by electrolysis rapidly kill microorganisms, ensuring high disinfection efficiency.
**Longevity: Titanium electrodes exhibit excellent corrosion resistance and stability, maintaining efficient disinfection over extended periods.
**Safety: The hydrogen gas generated during electrolysis is a clean energy source that can be recycled or safely vented.

4,  Application Examples:

** Titanium anodes have widespread applications in healthcare, food and beverage, drinking water treatment, swimming pools, and more.
** In swimming pool disinfection, titanium anodes electrolyze sodium chloride solution to generate chlorine gas and hypochlorous acid, effectively sanitizing the pool water while minimizing irritation to skin and reducing environmental pollution.

Product Parameters
 
Electrode combination anode * 7 or customization 
Electrode size 267mm*50mm*1.0mm or customization
Electrode combination weight 0.50Kg , Determined according to actual customization
Working current 15A or customization
Operating voltage 40V or customization

Product specifications: Custom production in the form of components or according to customer drawings.
 

Installation Instructions

 

Customization, Titanium Electrode Set for Bathtub Disinfection
Customization, Titanium Electrode Set for Bathtub Disinfection
 
Packaging & Shipping

Customization, Titanium Electrode Set for Bathtub Disinfection

Certifications

Customization, Titanium Electrode Set for Bathtub Disinfection

 
Our Advantages

Our factory located in Baoji, China's titanium industry base, with a strong R & D team and production capacity. Efficient to provide customers with customized services.


Customization, Titanium Electrode Set for Bathtub Disinfection
FAQ


Question 1: We are very satisfied with this product. Can I customize my logo on the product?
Answer 1: Of course. We offer customized services.

Question 2: I want to adjust the size of this product to meet our needs, can you meet it?
Answer 2: Yes, this exhibit is our standard, it's only for reference. Please provide your specific requirements or drawings, we will customize for you.

Question 3: What's the lead time for this product?
Answer 3: 3-5days.

Question 4: What's the lead time for customization?
Answer 4: Sample delivery time of fixed products: 3-5days.  Mass production delivery time: 21-30 days.






 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier