Euro charger
Input:100-240VAC ; 50/60Hz; 0.2A
Output: 5.0VDC; 1.0A 5W
Detailed Photos


Certifications
Item |
Country |
Certified |
Standard |
TUV |
EURO |
Approved |
EN62368-1
|
Product Description
Physical size: 34.00±1.0mm(L)* 21.50±1.0mm(W)* 41.00±1.0mm(H)

1,SCOPE
This document details theelectrical, mechanical and environmental specificationsof a switching power supply.
Description: Wall Mount
2, INPUT REQUIREMENTS
MIN. |
NORMAL |
MAX. |
90Vac |
100-240Vac |
264Vac |
Input Voltage & Frequency: The range of input voltage is from 90Vac to 264Vac
Input Current The maximum inputcurrent is In rush Current: 0.6A max. at 100-240Vac .
Inrush Current will not exceed 80A at 100-240Vac input and Max load for a cold start at 25ºC.
3,
OUTPUT FEATURES
Output Voltage |
Total Regulation |
Load Range |
MIN. |
MAX. |
Peak |
5V |
4.75-5.25V |
0A |
1A |
/ |
The maximum ripple must be less than 150mVp-p when subjected to the following
conditions:
1). Bandwidth: 20MHz
2). Add a 47uF/50V (Low ESR) electrolytic capacitor in parallel with a 100nF/50V ceramic
capacitor at the point of output load.
3). Line Voltage: 100-240Vac
4). Output Load: 0, 25%, 50%, 75%, 100%
5). Ambient: 25ºC
4.0 PROTECTION REQUIREMENT
4.1 OVER VOLTAGE PROTECTION
The power supply shall be hiccupped when output voltage reaches to its over -
voltage protection trigger point 7.5V Max.
The power supply shall fail but safe - the input power shall be less than W.
The power supply shall be self - recovering when the fault condition is
removed.
The power supply will go into latch-off mode, and have to OFF and ON the AC
input to restart the power supply.
4.2 OVER CURRENT & SHORT CIRCUIT PROTECTION
The power supply shall be hiccupped when operating any output in overload
condition (1.5A Max.), or when operating any output in a short circuit condition.
The power supply shall fail but safe - the input power shall be less than W.
The power supply shall be self - recovering when the fault condition is
removed.
The power supply will go into latch-off mode, and have to OFF and ON the AC
input to restart the power supply.
5.0 ENVIRONMENTAL CONDITIONS
5.1 OPERATING
The power supply shall be capable of operating continuously in any mode without
performance deterioration in the following environmental conditions.
5.1.1 Ambient Temperature: 0ºC ~40ºC @ full load
5.1.2 Relative Humidity: 20% ~ 98% Non-Condensing
5.1.3 Altitude: Sea level to 5,000m (Max).
5.2 NON - OPERATING
The power supply shall be capable of withstanding the following environmental
conditions extended periods of time, without sustaining electrical or mechanical
damage and subsequent operational deficiencies:
5.2.1 Ambient Temperature: -20ºC ~ +80ºC
5.2.2 Relative Humidity: 20% ~ 98% Non-Condensing
5.2.3 Altitude: Sea level to 12,600m (Max.)
6.0 ELECTRO MAGNETIC COMPATIBILITY
6.1 EMI STANDARDS
The power supply shall meet the radiated and conducted emission requirements
for EN55032
6.2 EMS STANDARDS
The power supply shall meet the following EMS standards EN55035
6.2.1 EN61000-4-2 Electrostatic Discharge (ESD)
Static - discharge test by contact or air should be conducted with Static -
discharge teeter, energy storage capacitance of 150pF, and discharge
resistance of 330Ω .
4KV contact discharge, 8KV air discharge,
Performance Criterion A
6.2.2 EN61000-4-3 RADIATED ELECTROMAGNETIC FIELDS (RS)
Radio- frequency Electromagnetic Field Susceptibility Test, RS, 80-1000MHz,
3V/m, 80%AM(1KHz), Performance Criterion A.
6.2.3 EN61000-4-4 Electrical Fast Transient / Burst (EFT)
Power Line to Line: 1KV
Line to earth: 1KV
Performance Criterion A
6.2.4 EN61000-4-5 LIGHTNING SURGE (1.2/50uS-8/20uS Combination Wave)
Lightning Surge voltage of differential and common modes shall be applied
across AC input lines and across input and frame ground.
Power Line to Line: 1KV
Line to Earth: 1KV
Performance Criterion A
6.2.5 EN61000-4-6 CONDUCTED RADIO FREQUENCY DISTURBANCES (CS)
Conducted Radio Frequency Disturbances Test, CS, 0.15-80 MHz, 3Vrms,
80%AM, 1 KHz, Performance Criterion A.
7.0 RELIABILITY AND QUALITY CONTROL
7.1 MTBF
The MTBF shall be at least 50,000 hours at 25ºC, full load, 115Vac/60Hz and
230Vac/50Hz input, following SR-332 issue03(2011).
7.2 BURN-IN
The power supply shall undergo a minimum of 4 hours Burn-In test at 40ºC ±5ºC
under full load and nominal input voltage for QA test.
The power supply shall undergo a minimum of 2 hours Burn-In test at 40ºC ±5ºC
under full load and nominal input voltage for mass production.
7.3 ELECTROLYTIC CAPACITOR LIFE TIME
The life time of Electrolytic Capacitor should be greater than 2 years under 120V
60Hz/ 230V 50Hz input @25ºC ambient condition with full load.
The Electrolytic Capacitor life calculated base on actual temperature measurement
and shall take into account all factors which affect life base on each capacitor
vendor's Electrolytic Capacitor life formula.(For example capacitor temperature and
ripple current).
7.4 DROP TEST
All types of wall mount and desktop power supply products are required to have a
drop test to be verified.
The testing height must be 75cm +/-1cm from the ground, drop one times for each
welding side of the product (total 6 times), drop on the 30mm hardwood surface.
All power supply products must meet the requirement on the specification and do
not have any isolation broken.
ENVIRONMENTAL COMPLIANCE
1 RoHS
Meet 2011/65/EU directive and its amendment (EU) 2015/863
2 PACKAGING
Meet EU94/62/EC directive
3 REACH
Meet EU 2006/1907/EC directive
4 WEEE (Waste Electrical and Electronic Equipment)
Meet EU 2012/19EC directive