Titanium-Ruthenium-Iridium Electrode Assembly, 20PCS Anode

Product Details
Customization: Available
Type: Metal Electrode
Cooling System: Radiator
Still deciding? Get samples of US$ 1200/Piece
Request Sample
Manufacturer/Factory, Other, Group Corporation
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
32800000 HKD
Plant Area
>2000 square meters
  • Titanium-Ruthenium-Iridium Electrode Assembly, 20PCS Anode
  • Titanium-Ruthenium-Iridium Electrode Assembly, 20PCS Anode
  • Titanium-Ruthenium-Iridium Electrode Assembly, 20PCS Anode
  • Titanium-Ruthenium-Iridium Electrode Assembly, 20PCS Anode
  • Titanium-Ruthenium-Iridium Electrode Assembly, 20PCS Anode
  • Titanium-Ruthenium-Iridium Electrode Assembly, 20PCS Anode
Find Similar Products
  • Overview
  • Detailed Photos
  • Product Parameters
  • Product Description
  • Installation Instructions
  • Packaging & Shipping
  • Certifications
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
TRIES SERIES
Materials
Titanium Electrode
Electrolyte Temperature
25~40ºC
Certification
ISO9001/ISO14001/ISO45001
Support Customization
Yes
MOQ
1 Set
Lead Time
5-7 Days
Base Material
Ta1 Titanium Plate
Coating Material
Ruthenium-Iridium
Coating Thickness
8um
Current Density
300~350A/M²
Durability
13080 Hours
Size
149*130*2.0mm
Weight
4.5kg
Transport Package
Individual Packing + Wooden Box
Specification
Size: 149*130*2.0mm
Trademark
CHB or customization
Origin
China
Production Capacity
50000PCS/Month

Product Description

 
Detailed Photos

 

Upright picture
Titanium-Ruthenium-Iridium Electrode Assembly, 20PCS Anode

Side picture

Titanium-Ruthenium-Iridium Electrode Assembly, 20PCS Anode
 
Product Parameters
Size 149*130*2.0mm
Current density 300~350A/m²
Durability 13080 hours
Electrolyte temperature 25~40ºC
Support customization YES
 
Product Description

Working Principle of Ruthenium-Iridium Electrolysis Plate for Electrolyzing Sodium Hypochlorite

The ruthenium-iridium electrolysis plate functions in the electrolysis of sodium hypochlorite by leveraging the principles of an electrolytic cell and the catalytic effects of ruthenium-iridium oxide. Here's a detailed explanation of its working principle:

  1. Electrolytic Cell Setup:
    • The electrolytic cell comprises a cathode, an anode (the ruthenium-iridium electrolysis plate), and an electrolyte solution (typically a chloride-containing aqueous solution, such as brine).
    • The ruthenium-iridium oxide coating on the anode exhibits excellent conductivity and catalytic activity.
  2. Electrolysis Process:
    • When a direct current power source is applied, reduction and oxidation reactions occur at the cathode and anode, respectively.
    • At the anode (ruthenium-iridium electrolysis plate), chloride ions (Cl-) lose electrons and combine with hydrogen ions (H+) in the water, generating hypochlorous acid (HClO) and hydroxide ions (OH-). Hypochlorous acid is the primary active ingredient in electrolyzed sodium hypochlorite, known for its strong oxidizing properties.
    • The simplified electrolytic reaction can be expressed as: 2Cl- + 2HO → 2HClO + H2↑ + 2e- (Note: This equation is a simplification; in reality, hydrogen gas formation primarily occurs at the cathode, and the reaction is more complex).
  3. Formation of Sodium Hypochlorite:
    • In practical applications, to obtain sodium hypochlorite (NaClO), the electrolytic conditions are controlled to facilitate the combination of hypochlorous acid with sodium ions (Na+) in the solution, forming sodium hypochlorite.
    • Sodium hypochlorite is a potent oxidant capable of disrupting cell membranes, proteins, nucleic acids, and other biological molecules, effectively killing bacteria, viruses, and other microorganisms.
  4. Advantages:
    • The ruthenium-iridium electrolysis plate exhibits excellent corrosion resistance and electrochemical stability, enabling long-term operation in harsh electrolytic environments.
    • The electrolysis process produces sodium hypochlorite, which is non-toxic, leaves no residue, and is environmentally friendly.

Applications of Disinfection Machines

Disinfection machines, operating through mechanical principles to generate physical or chemical disinfectants to eradicate harmful organisms, have diverse applications:

  1. Medical Sector:
    • Disinfection of hospital wards, operating rooms, laboratories, and other facilities to prevent cross-contamination.
    • Sterilization of medical instruments, surgical tools, beds, and other equipment to ensure medical safety.
  2. Daily Life:
    • Sanitizing households, such as wardrobes, shoe cabinets, clothing, bedding, floors, etc.
    • Disinfecting kitchens, bathrooms, and other areas prone to bacterial growth to maintain healthy living conditions.
  3. Public Spaces:
    • Disinfecting schools, kindergartens, offices, malls, restaurants, and other public venues to enhance public hygiene.
    • Sanitizing public transportation (e.g., buses, subways) to reduce the risk of virus transmission.
  4. Special Environments:
    • Disinfecting industrial production lines, food processing factories, livestock farms, and other specialized environments to ensure production safety and product quality.
    • Sterilizing scientific research laboratories, biosafety laboratories, and other high-demand environments to prevent the spread of harmful microorganisms.
  5. Other Applications:
    • As vital epidemic prevention equipment, disinfection machines are used to rapidly and efficiently eliminate airborne viruses and bacteria.
    • In environmental protection, they treat wastewater and exhaust gases, reducing pollutant emissions.

In summary, the ruthenium-iridium electrolysis plate plays a crucial role in the electrolysis of sodium hypochlorite, while disinfection machines, with their wide range of applications and effective disinfection capabilities, are instrumental in safeguarding public health and production safety.

Titanium-Ruthenium-Iridium Electrode Assembly, 20PCS Anode
Home disinfection
Titanium-Ruthenium-Iridium Electrode Assembly, 20PCS Anode
 

Installation Instructions
Titanium-Ruthenium-Iridium Electrode Assembly, 20PCS Anode

 

Packaging & Shipping

Titanium-Ruthenium-Iridium Electrode Assembly, 20PCS Anode

Certifications

Titanium-Ruthenium-Iridium Electrode Assembly, 20PCS Anode


 

Our Advantages

Our factory located in Baoji, China's titanium industry base, with a strong R & D team and production capacity. Efficient to provide customers with customized services.


Titanium-Ruthenium-Iridium Electrode Assembly, 20PCS Anode
FAQ


Question 1: We are very satisfied with this product. Can I customize my logo on the product?
Answer 1: Of course. We offer customized services.

Question 2: I want to adjust the size of this product to meet our needs, can you meet it?
Answer 2: Yes, this exhibit is our standard, it's only for reference. Please provide your specific requirements or drawings, we will customize for you.

Question 3: What's the lead time for this product?
Answer 3: 3-5days.

Question 4: What's the lead time for customization?
Answer 4: Sample delivery time of fixed products: 3-5days.  Mass production delivery time: 21-30 days.









 